EMG® inductors for low voltage are used in devices for the production of clean energy, such as wind or photovoltaic energy, as well as in inverters and power correction systems

 

 

Reactors > Test

Test

Test


The prototypes are further controlled thanks to the additional tests.We check that all our inductors respect the applicable regulations and laws in the electrical field. 

 

Prototype tests


-Temperature rise measurement with the resistance variation method as envisaged by CEI EN 60076-6 legislation

-Leaks in short-circuit

-Measurement of the saturation curve

 

Tests upon request


Harmonic distortion test to check the real working conditions of our inductors

We short-circuit the inductor and supply it with highly partialised voltage so that the nominal current can circulate. This current is notably distorted: the average THDi value recorded is 45-50%. The high voltage partialisation tends to put the magnetic circuit under strain and to highlight any noise problems that would not be detected at 50 Hz frequency.

 

Declaration of Conformity and homologations


As well as complying with the EN 60289 regulation, EMG® inductors are homologated cCSAus, therefore can be marketed and sold across North America. The Canadian Standards Association (CSA) checks and certifies that the products are compliant with the applicable standards in terms of safety and/or performance and it is the main mark in Canada. UL is the certifying mark for the United States of America. Thanks to an agreement with UL, CSA certifies the compliance of a product with all the applicable regulations for both the American and Canadian markets. This compliance is indicated by the cCSAus mark - featured by our inductors. 

 

 

Custom


Our products are highly customisable, therefore the descriptive parameters indicated in the catalogue are provided as a guide. According to the customer needs, the data is adapted to the desired product type.

Routine tests

-Voltage drop test

-Strength test

-Winding resistance

-Insulation resistance

Descrizione immagine

c - Canada,

CSA - certifying body

us - United States of America

Reactors > Data sheet

Data sheet

Data sheet

The EMG®  inductors are tailored-made solutions, depending on technical requirements, uses, applicable rules and standards, as well as technical feasibility.

 

Number of phases


Maximum nominal voltage



Frequency


Insulation class


Connections


Protection level


Maximum room temperature


Altitude


Compliant to regulations



1 (singlephase) / 3 (three-phase)


999V (600V products homologated for North-America)



50 / 60 Hz, on request other frequency


F / H


cable terminals / bars, on request other connections


IP00, on request other temperatures


Ta = 40°C, on request other temperatures


up to 1000 m


EN 60989 - EN 60076 - EN 61558


Reactors > Applications

Applications

 Applications




General use


PFC

UPS

Power Factor Correction (PFC)

Galvanic unit

Power electonic

Wind-powered generator (armonic filters)

Engine (limitation of the start-up current)

Converter

Inverter

Railway system (on the machines and signals)

Use for harmonic block on power factor correction 

with accordance at 5,6%, 7%, 14% 

Filter

Use for harmonic block with


Current distortion average degree  THDi 45%

Voltage distortion average degree  THDv 25%

Dedicated Filter

Start-up engine

Use for 10 HP up to 150 HP engines

Sized for 4 starting-up per hour, max of 2 consecutive startings

Drive or inverter

Use  upstream and/or downstream of an inverter or drive

Linearity 2In or higher

Voltage drops from 1% to 4% in the net voltage

 

On request  test at different working conditions from 30 to 1,900 Hz of carrier frequency. A switching ripple can be added from 1 to 10 kHz

Reactors > Custom

Custom

Custom

Dimensions


Execution


Maximum Insulation Voltage


Thermal sensor


Connections

standard


 

on request




Insulation class


Resin impregnated


Protection level


Maximum room temperature


Maximum overtemperature


Air cooling


Simulation test

on request or technical specification


horizontal / vertical


on request or technical specification


type PTC / NC thermal contact


cable terminals

Copper / Aluminium bars

Termoplastic terminals


Customised screw terminal board

Weidmueller, Synflex, Phoenix clamps

Pre-wiring ending wires


F / H


no / yes


IP00, on request other IP


Ta = 40°C, or on request


on request or technical specification


natural air / forced air


on request or technical specification


The use of resin impregnated reactors allows to have high insulation levels of 30 kV, hence passing the water immersion test. 


This type of reactor is used in environments with a high level of humidity, condensation or dust, which is typical of railway applications

It is possible to put the transformer inside a box, with protection level on request

We can make simulation test with harmonic generator to check the temperature and noise in real working conditions.

Reactors > North America Homologation

Homologation

North America Homologation

File 228479

Reference regulation CSA C22.2 N° 66/06

Reference regultion UL 5085

Three-phase inductors with homologation for North-America


Maximum voltage 600 V


Maximum working current 824 A


Wirking frequency 50/60 Hz


Insulation class F / H


Insulation 4000 V


Protection level IP 00

Descrizione immagine
Descrizione immagine

c - Canada,

CSA - certifying body

us - United States of America